Lecteur de microplaques multimode hybride Synergy H4
Synergy™ H4 with Hybrid Technology™ is a patent-pending multi-mode detector that combines the optical systems of Synergy Mx and Synergy 2 in one compact instrument. It is the ideal instrument for research and drug discovery applications when having to choose between flexibility and performance is not an option. The monochromator-based optics provides a high level of flexibility; any wavelength can be used from the low UV to the near infrared. The quadruple grating optical system, equipped with a variable bandpass selection system, is ideal for spectral scanning applications. The filter-based optics use dichroic mirrors for enhanced performance. This system is faster and more sensitive than the monochromator optics. A dual reagent dispenser option is available for inject and read assays such as flash luminescent assays and fluorescent ion channel assays. Additional read modes include: fluorescence polarization, time resolved fluorescence and AlphaScreen/AlphaLISA.
Watch this interview at SelectScience.tv with Marina Bruss from Analytica 2010 to learn more about the Synergy H4 Hybrid Multi-Mode Microplate Reader.
HTRF® and the HTRF logo are registered trademarks of Cisbio.
Transcreener® is a registered trademark of BellBrook Labs.
The LanthaScreen™ and GeneBLAzer® technologies from Invitrogen have been validated on BioTek instruments.
- Hybrid Technology : une détection à base de filtres hautes performances, une détection à monochromateur flexible
- Modes de détection : intensité de fluorescence (FI), polarisation de fluorescence (FP), fluorescence en temps résolu (TRF), TR-FRET, luminescence haute performance, absorbance UV-visible, AlphaScreen/AlphaLISA.
- Compatible avec la plaque multivolume Take3™, avec des microspots de 2 µL pour les dosages à faible volume
- Système de quadruple monochromateur et sélection variable de la bande-passante: la conception optique de Synergy H4 intègre deux doubles monochromateurs. Cette quadruple conception offre des performances de balayage spectral et une flexibilité optimales. Le système de sélection variable de la bande-passante permet une utilisation de l'appareil tout en souplesse.
- Filtres bloquant la fluorescence profonde et miroirs dichroïques : la combinaison de filtres et de miroirs dichroïques du Synergy H4 offre les meilleures performances possibles sur les applications de fluorescence, de fluorescence en temps résolu, de polarisation de la fluorescence et AlphaScreen/AlphaLISA.
Le Synergy™ H4 est le lecteur hybride de seconde génération de BioTek. À l’instar du Synergy 4, il offre les avantages d’une association de détection à base de filtre et de détection à base de monochromateur.
Synergy™ H4 | |||||||
| Réf. # | Absorbance | LUM | FI (Filtres et monos) | FP | TRF | Injecteurs | Logiciel |
| H4MF | • | Gen5™ inclus | |||||
| H4MFD | • | • | |||||
| H4MFA | • | • | |||||
| H4MFAD | • | • | • | ||||
| H4MLF | • | • | |||||
| H4MLFD | • | • | • | ||||
| H4MLFA | • | • | • | ||||
| H4MLFAD | • | • | • | • | |||
| H4MLFPTA | • | • | • | • | • | ||
| H4MLFPTAD | • | • | • | • | • | • | |
| H4MFPT | • | • | • | ||||
| H4MFPTD | • | • | • | • | |||
| H4MLFPT | • | • | • | • | |||
| H4MLFPTD | • | • | • | • | • | ||
| H4MFPTA | • | • | • | • | |||
| H4MFPTAD | • | • | • | • | • | ||
| Général | |
| Sélection de longueurs d'ondes | Hybrid Technology (en instance de brevet) Quadruple monochromateur et filtres/miroirs dichroïques |
| Méthode de détection | Fluorescence, fluorescence à résolution temporelle, polarisation de fluorescence, AlphaScreen / AlphaLISA ®, luminescence, absorbance des UV-visibles |
| Méthode de lecture | Point final, cinétique, balayage spectral, balayage de la zone des puits |
| Types de microplaque | Système de monochromateur pour les microplaques de 1 à 384 puits Système de filtre pour les microplaques de 1 à 1536 puits Microplaques PCR Compatible avec la plaque multivolume Take3 avec microspots de 2 µL |
| Contrôle de température | 4°C au-dessus de la température ambiante à 50°C |
| Agitation | Oui |
| Logiciels | Gen5™ Inclus Controle par port USB ou série |
| Automatisation | Oui |
| AlphaScreen/AlphaLISA | |
| Source de lumière | Tungsten Halogen Lamp |
| Sensibilité | 100 amol of biotinylated-LCK-P peptide, 25 µL/well in 384-well plate |
| La gamme dynamique | >6 decades |
| Vitesse de lecture | 2 minutes typical for 96-well plate |
| Système de détection | Ultra Low Noise PMT |
| Absorbance | |
| Source lumineuse | Lampe flash au xénon SQ |
| Sélection de longueurs d'onde | Monochromator |
| Gamme de longueurs d'onde | 230 - 999 nm, incréments de 1 nm |
| Bande Passante | 2 nm (230-285 nm), 4 nm (>285 nm) |
| Gamme dynamique | 0 - 4.0 DE |
| Résolution | 0.0001 OD |
| Correction du trajet optique | Oui |
| Précision de longueur d'onde du monochromateur | +/- 2 nm |
| Répétabilité de la longueur d'onde du monochromateur | +/- 0.2 nm |
| Précision de la DO | < 1% à 2.0 DE (standard) < 3% à 3.0 DE (standard) |
| Linéarité de la DO | < 1% de 0 à 3.0 DE (standard) |
| Répétabilité de la DO | < 0.5% à 2.0 DE (standard) |
| Lumière parasite | 0.03% à 230 nm (standard) |
| Vitesse de lecture | 96: 11 secondes 384: 22 secondes |
| Intensité de fluorescence | |
| Sensibilité | Monochromateurs : Fluorescéine 2,5 pM standard (microplaque à 384 puits : 0,25 fmol/puits) – Haut Fluorescéine 5 pM standard (microplaque à 384 puits : 0,5 fmol/puits) – Bas Filtres/miroirs : Fluorescéine 1 pM standard (microplaque à 384 puits : 0,1 fmol/puits) |
| Source lumineuse | Lampe halogène au tungstène Lampe flash au xénon à haute énergie |
| Sélection de longueurs d'onde | Doubles monochromateurs (haut/bas) et filtres bloquant la fluorescence profonde/miroirs dichroïques (haut) |
| Gamme de longueurs d'onde | Monochromateurs : 250-900 nm Filtres : 200-700 nm (900 nm en option) |
| Gamme dynamique | Monochromateurs : 5 décades Filtres/miroirs : 6 décades |
| Bande Passante | Monochromateurs : variable 9, 13,5 ; 17 ; 20 nm Filtres : en fonction du filtre, de 5 nm à >100 nm |
| Système de détection | PMT à décalage vers le rouge pour le système de monochromateur PMT à faible bruit pour le système à base de filtre |
| Vitesse de lecture | 96: 11 secondes 384: 22 secondes 1536: 42 secondes |
| Luminescence | |
| Sensibilité | 10 amol ATP (standard) (flash) |
| Gamme de longueurs d'onde | 300 - 700 nm |
| Gamme dynamique | > 60 ans |
| Polarisation de fluorescence | |
| Source lumineuse | Halogène au tungstène |
| Sensibilité | Fluorescéine 3 mP à 1 nM (standard) |
| Sélection de longueurs d'onde | Filtres bloquant la fluorescence profonde/miroirs dichroïques (haut) |
| Gamme de longueurs d'onde | 400 - 700 nm (300-900 nm en option) |
| Fluorescence à résolution temporelle | |
| Source lumineuse | Lampe flash au xénon à haute énergie |
| Sensibilité | Europium 60 fM standard avec filtres (6 amol/puits pour les microplaques à 384 puits) |
| Sélection de longueurs d'onde | Filtres bloquant la fluorescence profonde/miroirs dichroïques (haut) Double monochromateur (haut/bas) |
| Gamme de longueurs d'onde | Filtres : 200-700 nm (900 nm en option) Monochromateurs : 250-900 nm |
| Distributeurs de réactifs | |
| Nombre | 2 pompes à seringue |
| Volume de distribution | 5-10000µL par incréments de 1µL |
| Volume mort | 1,1 mL, 100 µL avec rétrobalayage |
| Caractéristiques physiques | |
| Alimentation | 250 Watts max. |
| Dimensions | 17"W x 20.9"D x 15"H (43.5 x 53.1 x 38.1 cm) |
| Poids | 78 lbs (35 kg) |
| Réglementation | |
| Réglementation | Tous les instruments pour microplaques de BioTek sont certifiés CE et NRTL Safety Agency. Pour de plus amples informations sur les certifications et la conformité aux normes, veuillez contacter BioTek. |
Les spécifications sont susceptibles d'être modifiées.
Standard (inclus)

Logiciel d'analyse et de collecte de données Gen5
En option

Dispositif d'empilement de microplaques BioStack

Manipulateur de microplaques BioStack Twister II







Lights...Camera...Epoch! Enter our video contest to WIN an Epoch System for your lab.
Watch "The Lab" and sign up to win a VT Teddy Bear!