Today's research requires that instrumentation be cost effective, reliable and easy to use. In response to those requirements, BioTek Instruments has developed the Synergy™ HT Multi-Mode Microplate Reader. This plate reader for fluorescence, absorbance and luminescence measurements was designed with an emphasis on superior performance in all detection methods. Unlike many multi-mode microplate readers, the Synergy HT utilizes a unique dual-optics design.

When making fluorescence determinations, the Synergy HT uses a tungsten halogen lamp with interference filters for wavelength specificity in conjunction with a PMT detector. The tungsten halogen lamp produces a large amount of light at a constant intensity, providing increased sensitivity and repeatability. Specially designed fluorescent interference filters prevent light leakage from excitation wavelength to the emission wavelength, particularly important with fluorescent compounds with small Stoke's shifts. In addition, the ability to use filters with different bandpasses allows the investigator to tailor their fluorescence measurements to their experiment more effectively.

The low noise PMT is operated in digital photon integration mode for high performance luminescence measurements.

When absorbance measurements are made, the instrument switches to a Xenon Flash Lamp and a monochromator for wavelength selection. The use of a xenon flash lamp allows for both UV and visible light absorbance measurements. The monochromator provides wavelength selection from 200 to 999 nm in 1 nm increments. Thus, dual-optics design allows the investigator to have three different reading modes without compromise.

The Synergy HT has a 4-Zone™ temperature control system that ensures superior temperature uniformity necessary for kinetic assays. With a compact footprint and robot-accessible carrier design, the Synergy HT is also compatible with most automated systems. A Reagent Dispenser option is available. Reader control is via BioTek's Gen5™ Data Analysis Software. USB and serial ports are available for easy connectivity.

 

US Federal Government customers:

This product is available on GSA contract. Contact BioTek Customer Care with questions or submit a Quote Request Form to receive pricing and information on specific models (please note GSA Contract in the Comments field).

Dual-Luciferase is a trademark of Promega Corporation and is registered with the U.S. Patent and Trademark office.

 Take3 Trio Compatible       

  • Modes de lecture automatique de la fluorescence supérieure et inférieure optimisés pour les essais sensibles et homogènes et à cellules précaractérisées
  • Ajustement automatique de la hauteur de la sonde contrôlée par le logiciel avec capteur de plaque intégré visant à éviter les défaillances de sondes
  • Monochromateur de balayage pour les balayages de longueur d'onde permettant d'identifier l'absorbance maximale et de fournir une analyse spectrale complète
  • Mesures de luminescence avec détection supérieure pour une meilleure sensibilité
  • Lit les microplaques de 6 à 384 cupules, y compris les plateaux PCR et les plaques Terasaki
  • Balayage des zones à cupules pour les essais à cellules précaractérisées communs
  • Capacité de fluorescence à résolution temporelle
  • Distributeurs de réactifs doubles
  • Ports série et USB pour une connexion facile
  • Comprend le logiciel Gen5™
  Modèle Synergy™ HT
 Référence

SIAFRT

SIAFRTD

SIAFRT- PERSONNALISÉ

SIAFRTD- PERSONNALISÉ

 Absorbance
 Fluorescence
 Luminescence
 Résolution temporelle
 Fluorescence
 Incubation
 Agitation
 2 injecteurs    
 Sondes de 3 mm (supérieure)/5 mm
 (inférieure)
   
 Sondes personnalisées    
 Logiciels Gen5™ inclus dans toutes les configurations

*Les configurations possibles de sondes personnalisées sont les suivantes : 1,5 mm (supérieure)/3,0 mm (inférieure) ; 3,0 mm (supérieure)/3,0 mm (inférieure) ; 3,0 mm (supérieure)/1,5 mm (inférieure) et choix du type PMT (faible bruit ou étendu rouge).

 

Général
Méthode de détection Fluorescence, fluorescence à résolution temporelle, luminescence, absorbance des ultraviolets
Méthode de lecture Point final, cinétique, balayage spectral, balayage de la zone des puits
Types de microplaque

Plaques de 6 à 384 puits
Plaques PCR

Compatible avec la plaque multivolume Take3 et microspots de 2 µL

Contrôle de température 4 ° C au-dessus de la température ambiante jusqu'à 50 ° C; + 0,5 ° C à 37 ° C
Agitation Oui
Logiciels Gen5™ inclus.
Contrôle par port USB ou série.
Automatisation Oui
Absorbance
Source lumineuse Lampe flash au xénon SQ
Sélection de longueurs d'onde Monochromateur
Gamme de longueurs d'onde 200-999 nm, incréments de 1 nm
Bande Passante 2,4 nm
Gamme dynamique 0-4,0 DE
Résolution 0,001 DE
Correction du trajet optique Oui
Précision de longueur d'onde du monochromateur +/-2 nm
Répétabilité de la longueur d'onde du monochromateur +/-0,2 nm
Précision de la DO <1% at 2.0 DE (standard)
<3% à 3,0 DE (standard)
Linéarité de la DO <1% de 0 à 3,0 DE (standard)
Répétabilité de la DO <0,5 % à 2,0 DE (standard)
Lumière parasite 0,03 % à 230 nm (standard)
Vitesse de lecture 96 : 14 secondes
384 : 26 secondes
Intensité de fluorescence
Sensibilité Fluorescéine 5 pM (standard) (plaque à 96 puits : 1 fmol/puits) – haut et bas
Source lumineuse Tungstène-halogène Lampe flash au xénon SQ
Sélection de longueurs d'onde Filtres de blocage en profondeur
Gamme de longueurs d'onde 300 à 700 nm ( 200 à 900 nm en option )
Gamme dynamique 50 ans
Bande Passante Dépendant du filtre
Système de détection PMT
Vitesse de lecture 96 puits : 31 secondes
384 puits : 80 secondes
Luminescence
Sensibilité 30 amol ATP (standard) (flash)
Gamme de longueurs d'onde 300-700 nm
Gamme dynamique >6 decades
Système de détection PMT à faible bruit
Fluorescence à résolution temporelle
Source lumineuse Lampe flash au xénon SQ (en option)
Sélection de longueurs d'onde Monochromateur
Distributeurs de réactifs
Nombre 2 pompes à seringue
Volume de distribution 5-1000 µL par incréments de 1 µL
Volume mort 1,1 mL, 100 µL avec rétrobalayage
Caractéristiques physiques
Alimentation 100-240 V c.a. 50/60 Hz
Dimensions 16 po. L x 15 po. P x 10 po. H (40,6 x 38 x 25,4 cm)
Poids 40 livres (18 kg)
Réglementation
Réglementation Pour les diagnostics in vitro. Tous les instruments pour microplaque BioTek portent la marque CE et celle de l'agence de sécurité NRTL (laboratoires de test de renommée nationale). Pour obtenir des détails sur la conformité aux normes et homologations, veuillez contacter BioTek.

Les spécifications sont susceptibles d'être modifiées.

Standard (inclus)

Logiciel d'analyse et de collecte de données Gen5

Logiciel d'analyse et de collecte de données Gen5

Le nouveau logiciel Gen5™ de BioTek propose une interface logique qui vous permet de passer facilement des paramètres de lecture au format de plaque, de la réduction des données aux différentes options d'export des données. Cette conception intuitive, comprenant le protocole pas-à-pas StepWise™ exclusif et  la puissance de réduction des données de Gen5, améliorera grandement l'efficacité du laboratoire.


En option

Dispositif d'empilement de microplaques BioStack

Dispositif d'empilement de microplaques BioStack

BioStack™ apporte des fonctionnalités d'automatisation aux gammes Synergy™, PowerWave™, ELx405™, EL406™, Multiflo™, MicroFlo™ Select, MicroFill™ et Precision™ de BioTek.


Standard (inclus)

Câbles

75034 Serial Cable, Modem (9-pin female to 9-pin male) cet accessoire a une photo
75108 USB Cable (male A to male B) cet accessoire a une photo

Manuel de l'utilisateur

MANUAL Operator's manuals can be obtained via the Customer Resource Center

En option

Flacons et tubes

7112186 3 feet (1 meter) tubing for Synergy dispenser box

Câbles

75053 Serial Cable, Null Modem (9-pin female to 25-pin female) cet accessoire a une photo

Accessoires de filtre

7080541 Empty Filter Wheel for Synergys and FLx800 cet accessoire a une photo
7082073 Plug (Dummy filter) for Synergys and FLx800 cet accessoire a une photo
7082075 Retainer Clip for Synergys and FLx800 cet accessoire a une photo

Filtres

7082248 310/20 nm Fluorescence Filter cet accessoire a une photo
7082250 320/20 nm Fluorescence Filter cet accessoire a une photo
7092150 330/20 nm Fluorescence Filter cet accessoire a une photo
7082263 330/80 nm Fluorescence Filter cet accessoire a une photo
7082254 340/11 nm Fluorescence Filter cet accessoire a une photo
7082230 340/30 nm Fluorescence Filter cet accessoire a une photo
7082220 360/40 nm Fluorescence Filter cet accessoire a une photo
7092152 380/11 nm Fluorescence Filter cet accessoire a une photo
7082228 380/20 nm Fluorescence Filter cet accessoire a une photo
7092153 395/25 nm Fluorescence Filter cet accessoire a une photo
7082242 400/10 nm Fluorescence Filter cet accessoire a une photo
7082205 400/30 nm Fluorescence Filter cet accessoire a une photo
7092154 405/20 nm Fluorescence Filter cet accessoire a une photo
7092155 410/10 nm Fluorescence Filter cet accessoire a une photo
7092200 410/80 nm Fluorescence Filter cet accessoire a une photo
7082270 420/27 nm Fluorescence Filter cet accessoire a une photo
7082206 420/50 nm Fluorescence Filter cet accessoire a une photo
7082227 440/30 nm Fluorescence Filter cet accessoire a une photo
7082207 440/40 nm Fluorescence Filter cet accessoire a une photo
7082208 450/50 nm Fluorescence Filter cet accessoire a une photo
7082222 460/40 nm Fluorescence Filter cet accessoire a une photo
7092157 470/40 nm Fluorescence Filter cet accessoire a une photo
7092158 475/20 nm Fluorescence Filter cet accessoire a une photo
7092159 485/10 nm Fluorescence Filter cet accessoire a une photo
7082221 485/20 nm Fluorescence Filter cet accessoire a une photo
7082209 485/40 nm Fluorescence Filter cet accessoire a une photo
7092160 490/10 nm Fluorescence Filter cet accessoire a une photo
7092162 500/20 nm Fluorescence Filter cet accessoire a une photo
7082256 500/27 nm Fluorescence Filter cet accessoire a une photo
7082218 508/20 nm Fluorescence Filter cet accessoire a une photo
7092201 515/30 nm Fluorescence Filter cet accessoire a une photo
7082246 516/20 nm Fluorescence Filter cet accessoire a une photo
7092163 520/10 nm Fluorescence Filter cet accessoire a une photo
7092164 520/20 nm Fluorescence Filter cet accessoire a une photo
7082247 528/20 nm Fluorescence Filter cet accessoire a une photo
7082223 530/25 nm Fluorescence Filter cet accessoire a une photo
7092166 530/30 nm Fluorescence Filter cet accessoire a une photo
7092167 532/40 nm Fluorescence Filter cet accessoire a une photo
7092168 540/15 nm Fluorescence Filter cet accessoire a une photo
7082249 540/25 nm Fluorescence Filter cet accessoire a une photo
7082253 540/35 nm Fluorescence Filter cet accessoire a une photo
7092169 540/45 nm Fluorescence Filter cet accessoire a une photo
7082210 545/40 nm Fluorescence Filter cet accessoire a une photo
7092170 550/10 nm Fluorescence Filter cet accessoire a une photo
7092171 556/10 nm Fluorescence Filter cet accessoire a une photo
7092172 560/10 nm Fluorescence Filter cet accessoire a une photo
7082215 560/15 nm Fluorescence Filter cet accessoire a une photo
7082211 560/20 nm Fluorescence Filter cet accessoire a une photo
7082212 560/40 nm Fluorescence Filter cet accessoire a une photo
7092173 570/10 nm Fluorescence Filter cet accessoire a une photo
7082264 570/100 nm Fluorescence Filter cet accessoire a une photo
7092174 575/10 nm Fluorescence Filter cet accessoire a une photo
7082245 575/15 nm Fluorescence Filter cet accessoire a une photo
7092175 580/10 nm Fluorescence Filter cet accessoire a une photo
7082244 580/50 nm Fluorescence Filter cet accessoire a une photo
7092176 585/10 nm Fluorescence Filter cet accessoire a une photo
7092177 590/10 nm Fluorescence Filter cet accessoire a une photo
7082225 590/20 nm Fluorescence Filter cet accessoire a une photo
7082224 590/35 nm Fluorescence Filter cet accessoire a une photo
7092178 596/15 nm Fluorescence Filter cet accessoire a une photo
7082252 600/40 nm Fluorescence Filter cet accessoire a une photo
7092179 610/10 nm Fluorescence Filter cet accessoire a une photo
7082251 620/15 nm Fluorescence Filter cet accessoire a une photo
7082213 620/40 nm Fluorescence Filter cet accessoire a une photo
7092180 625/10 nm Fluorescence Filter cet accessoire a une photo
7092181 635/20 nm Fluorescence Filter cet accessoire a une photo
7082214 635/32 nm Fluorescence Filter cet accessoire a une photo
7092182 645/10 nm Fluorescence Filter cet accessoire a une photo
7082257 645/15 nm Fluorescence Filter cet accessoire a une photo
7082226 645/40 nm Fluorescence Filter cet accessoire a une photo
7092183 660/10 nm Fluorescence Filter cet accessoire a une photo
7092184 665/34 nm Fluorescence Filter cet accessoire a une photo
7092185 670/10 nm Fluorescence Filter cet accessoire a une photo
7092186 670/20 nm Fluorescence Filter cet accessoire a une photo
7092187 680/10 nm Fluorescence Filter cet accessoire a une photo
7092188 680/20 nm Fluorescence Filter cet accessoire a une photo
7082229 680/30 nm Fluorescence Filter cet accessoire a une photo
7092189 690/10 nm Fluorescence Filter cet accessoire a une photo
7092190 700/20 nm Fluorescence Filter cet accessoire a une photo
7092191 710/20 nm Fluorescence Filter cet accessoire a une photo
7092192 730/40 nm Fluorescence Filter cet accessoire a une photo
7092193 760/20 nm Fluorescence Filter cet accessoire a une photo
7092194 760/34 nm Fluorescence Filter cet accessoire a une photo
7092196 785/20 nm Fluorescence Filter cet accessoire a une photo
7092197 807/25 nm Fluorescence Filter cet accessoire a une photo
7092198 818/40 nm Fluorescence Filter cet accessoire a une photo

Supports pour laboratoire

7302030 Cuvette Adapter cet accessoire a une photo

Divers

7270512 Bio-Cell Adapter Plate Assemblée cet accessoire a une photo
7272051 Bio-Cell 1 cm Quartz Vessel cet accessoire a une photo

Packages d'homologation des produits

7090521 Synergy HT Qualification Package

plaque Micro Volume Take3

TAKE3 Take3 Micro-Volume Plate cet accessoire a une photo

Plaques de test et réactifs

98155 Sodium Fluorescein Powder (1 mg vial) cet accessoire a une photo
7092092 Fluorescence Test Plate cet accessoire a une photo
7120779 BioTek QC Check Solution #1 - Yellow (25 mL) cet accessoire a une photo
7120782 BioTek QC Check Solution #1 - Yellow (125 mL) cet accessoire a une photo
7260522 Absorbance Test Plate cet accessoire a une photo

Demande un devis